0
0
Cart
Your shopping cart is empty!
It's never too late to make things right :)

750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray

750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray
750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray
750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray
750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray
New
Pre-Order
Date Available: 18/06/2026
Article: 750-8216
Brand: Wago
72,469.32 грн.
Payment
Delivery
Delivery by Nova Poshta
The nearest branch addresses can be viewed on the map.
from
150.00 грн.
Pickup (Kyiv)
Pickup (Kyiv)
For free

Description 750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray

The PFC200 Controller is a compact PLC for the modular WAGO I/O System. Besides network and fieldbus interfaces, the controller supports all digital, analog and specialty modules found within the 750/753 Series.

Two ETHERNET interfaces and an integrated switch enable line topology wiring.

An integrated Webserver provides user configuration options, while displaying PFC200 status information.

Besides the processing industry and building automation, typical applications for the PFC200 include standard machinery and equipment control (e.g., packaging, bottling and manufacturing systems, as well as textile, metal and wood processing machines).

Programming per IEC 61131-3

  • Programmable with CODESYS V3.5 from Firmware Release 23, WAGO-I/O-PRO V2.3 or e!COCKPIT up to Firmware Release 22
  • Direct connection of WAGO's I/O modules
  • 2 x ETHERNET (configurable), RS-232/-485, CAN, CANopen, PROFIBUS DP Slave
  • Linux operating system with RT‐Preempt patch
  • Configuration via CODESYS, e!COCKPIT or Web-Based Management user interface
  • Maintenance-free

Main attributes 750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray

Connection data
Connection technology: communication/fieldbus PROFIBUS: 1 x D-sub 9 socket; CANopen: 1 x D-sub 9 plug; Modbus (TCP, UDP): 2 x RJ-45; Modbus RTU: 1 x D-sub 9 socket; RS-232 serial interface: 1 x D-sub 9 socket; RS-485 interface: 1 x D-sub 9 socket
Connection technology: device configuration 1 x Male connector; 4-pole
Connection technology: field supply 6 x CAGE CLAMP®
Connection technology: system supply 2 x CAGE CLAMP®
Connection type 1 System/field supply
Fine-stranded conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Strip length 8 … 9 mm
Environmental requirements
Ambient temperature (operation) 0 … +55 °C
Ambient temperature (storage) -25 … +85 °C
EMC emission of interference per EN 61000-6-3, marine applications
EMC immunity to interference per EN 61000-6-2, marine applications
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Fire load 2.883 MJ
Mounting position Horizontal left, horizontal right, horizontal up, horizontal down, vertical top and vertical bottom
Mounting type DIN-35 rail
Operating altitude without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
Permissible H₂S contaminant concentration 10 ppm
Permissible SO₂ contaminant concentration 25 ppm
Pollution degree 2 per IEC 61131-2
Protection type IP20
Relative humidity (without condensation) 95 %
Shock resistance 15g per IEC 60068-2-27
Vibration resistance 4g per IEC 60068-2-6
Mechanical data
Color light gray
Conformity marking CE
Housing material Polycarbonate; polyamide 6.6
Weight 260.7 g
Physical data
Depth 71.9 mm
Depth from upper-edge of DIN-rail 64.7 mm
Height 100 mm
Width 112 mm
Technical data
Communications Telecontrol protocols, requires an additional license
Configuration options Web-Based Management
CPU Cortex A8; 1 GHz
Current carrying capacity (power jumper contacts) 10 A
Data memory CODESYS V2: 64 MB; CODESYS V3: 128 MB
ETHERNET protocols SSH
Indicators LED (SYS, RUN, I/O, CAN, BF, DIA, U1 … U4) red/green/orange: Status system, program, internal data bus, CANopen, PROFIBUS, PROFIBUS diagnostics, status programmable by user (can be used via CODESYS library); LED (A, B) green: System power supply status, f
Input and output process image (internal) max. 1000 words/1000 words
Input and output process image (Modbus®) max. CODESYS V2: 1000 words/1000 words; CODESYS V3: 32000 words/32000 words
Input current (typ.) at nominal load (24 V) 550 mA
Internal memory (flash) 4096 MB
Isolation 500 V system/field
Main memory (RAM) 512 MB
Maximum input and output process image (CAN). 2000 words/2000 words
Maximum input and output process images (PROFIBUS). 244 bytes/244 bytes
Memory card slot Push-push mechanism; Cover lid (sealable)
Non-volatile hardware memory 128 kbyte
Non-volatile software memory 128. kbyte
Number of modules per node (max.) 250
Number of modules without a bus extension (max.) 64
Number of outgoing power jumper contacts 3
Operating system Real-time Linux (with PREEMPT_RT patch)
Program memory CODESYS V2: 16 MB; CODESYS V3: 32 MB
Programming environment WAGO-I/O-PRO V2.3 (based on CODESYS V2.3), up to Firmware Release 22
Programming languages per IEC 61131-3 Structured Text (ST)
Supply voltage (field) 24 VDC (-25 … +30 %); via power jumper contacts
Supply voltage (system) 24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)
Telecontrol protocols IEC 61850 (additional license as Client or Server)
Total current (system supply) 1,700 mA
Transmission medium (communication/fieldbus) ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
Transmission rate ETHERNET: 10/100 Mbit/s
Type of memory card SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO's memory card)
Visualization Web-Visu

Reviews about 750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray

0
0
1
0%
2
0%
3
0%
4
0%
5
0%

There are no reviews for this product.

Questions and Answers (FAQ) 750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray

There are no questions about this product.
750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray
750-8216 Controller PFC200;2nd Generation;2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave;light gray
Article:750-8216
Pre-Order
72,469.32 грн.
Recently viewed
icon_mes icon_teleg icon_viber icon_callback icon_email icon_instagram icon_facebook