Description Shear Beam KT805
Compact force sensor with integrated analogue amplifier and steel measuring body for measuring ranges up to 5 kN
- Compact shear beam with integrated analogue amplifier
- Output options 0…10 V, -10...+10 V, 4…20 mA
- Fast response time (< 1 ms)
- Force transmission via M8-thread
- Strain gauge full bridge
The KT805 force transducers with analogue output are characterised by their compact design (78x34x36 mm). The integrated amplifier provides output signals of 0...10 V, -10... +10 V, 4...20 mA for tension, pressure or both. With a cut-off frequency of 1.6 kHz (response time 650 µs), the electronics enables the measurement of forces in systems with fast production cycles. The force is applied via the M8 thread for measuring ranges up to 5 kN. The steel measuring body operates on the double bending beam principle. Mounting with two screws is simple and suitable for any flat, stable surface. The Wheatstone full bridge principle has been used for decades in this type of force sensor and ensures a long service life.
Main attributes Shear Beam KT805
Technical parameters
Reviews about Shear Beam KT805
There are no reviews for this product.
Questions and Answers (FAQ) Shear Beam KT805